Draeger Oil impactor, 8103560

Draeger Oil impactor, 8103560

  • Contact us
  • 235

Application Range:

Scale usable for detection of several concentrations (0.1, 0.5, & 1.0 mg/m³)
Signal at full synthetic oils
Lower detection limit 0.1 mg/³
Easy to read
Independent of oil type or viscosity


Ambient Operating Conditions:

Temperature:  10oC to 30oC

Humidity:  Up to 60% relative humidity

Pressure:  Only to be used for unstressed compressed air

Working Principle Dräger Impactor

Air flow passes through a plate with 20 spray holes (1).
Then the air flow is deflected by 90° and because of this the aerosol particles which are slow due to their mass - do not follow and deposit on the glass plate (2).
The deposited parts on the ground glass (2) are filled up by the oil causing a lightscattering.
This principle enables the visual detection of very small quantities of oil.